Description

This is a simple TRIAC AC load dimmer used to control the power of a resistive load such as incandescent lamp or heater element. The max load it can handle is 400VA. Such a circuit is often found on cheap commercial light dimmers and is proven to work reliable for the rated power.

The circuit is working by controlling the phase of the 220VAC voltage allowing the load to be powered for less than 360º of the full sine wave. Powering the load for smaller period than full sine wave delivers less power, so it has a dimming effect on the load.

400VA AC Light Dimmer

Control is done throught R2 potentiometer which controls the time needed for the C2 to be charged through R1-R2. C2 is charging until it reaches the breakdown voltage of DIAC D1 which then fires the TRIAC T1. Once the TRIAC is contacting the circuit is closed and the load receives power. 

The rate which C2 charges determinates the point on 220VAC sinewave where it reaches the breadown voltage of DIAC. So, slow C2 charging means that the DIAC conducts at the end of AC period and fast C2 charging means that DIAC conducts at the beggining of AC sine.

400VA AC Light Dimmer

Components L1 and C1 act as interference suppression filter reducing RF emmitions.

Circuit is directly connected to mains voltage, so lethal voltages present all over the board. Take care! The potentiometer should have a plastic spindle to provide sufficient isolation

Parts List
R1 3.9K - 1/4W
R2 470K linear potentiometer
C1 33nF / 400V capacitor
C2 100nF polyester capacitor
L1 19 turns of 0.8mm enamel wire on 4mm ferrite core
D1 DB4 diac
T1 BTA10-400B Triac
  heatsink for T1
  PCB screw terminals

Post a Comment

 